Service Parts
Controllers, Data Loggers and Data Management
 
 

DRS - Data Recording System  
Validate your HACCP program with Thermo King's in-transit data logger.
  

  • The industry's most user-friendly data logger
  • 400 days memory comes as standard
  • Built to last, completely sealed
  • 12/24V configuration, suitable for all vehicles
  • Simple to use, one-touch "Wintrac" software for Windows™
  • Download to computer or handheld portable printer
  • Meets HACCP requirements
  • East to install, mounts external or internal

DRC Specifications

Description
One-piece recording device with LCD window, key pad selection, event logging port, communication port and 128K memory as standard. The DRS kit includes a pre-wired and easy connect power cable and two (2) pre-calibrated sensors. An on-board battery ensures back-up protection of data and memory. Conforms to applicable European technical and safety standards, including AFNOR specification NFE18-150; EMC Directive 89/336/EEC (EMI/RFI) and EN 60529, Rating IP 67 (enclosure protection).

Dimensions:

8" x 4" x 2" approximate (200mm x 150mm x 50 mm)

Weight:

4.4 lbs (2kg)

Housing:

Anti-corrosion, sturdy housing with anodized aluminum shell and rubber end caps.

Key Pad: 

  Sealed membrane keypad 
  Select-Scroll-Print keys, identified by icons 
  Press key for desired function

Display:

  Liquid Crystal Display (LCD) of temperature values, events,      time, dates, and memory capacity 
  Resolution: 0.1°F (0.1°C) displayed 
  "Anti-fog" display

Sensors: 

  Two (2) sensors pre-calibrated and interchangeable 
  Accuracy: +/- 0.9°F at 32°F (+/- 0.5°C at 0°C) 
  Logging Frequency: 1, 5, 10, 15, 30, or 60 minute intervals

Logging Format: 

  Temperature recorded and stored in whole degrees

Logging Type: 

  Minimum value encountered during the logging period, or 
  Mean value computed during the logging period, or 
  Maximum value encountered during the logging period, or 
  Instantaneous value at the end of he logging period

Logging Range:

  Standard setting: -31°F to 77°F (-35°C to 25°C) 
  Optional settings: 5°F to 133°F (-15°C to 45°C) 
    -22°F to 86°F (-30°C to 30°C) 
    -49°F to 59°F (-45°C to 15°C) 

Memory Size: 

  Standard memory 128K i.e. 400 days memory at 15 minute      recording intervals (standard)

Special Features: 

  User configurable (simple and easy) 
  All critical parameter adjustments automatically recorded      and stored 
  Password protection

Installation: 

  Easy to install. Mounting hardware and installation drawing     supplied

Power Supply: 12V or 24V dc.

 

Part Number. 

Description

40-657

DRS - includes: pre-wored harness, two (2) sensors, and mounting hardware 

41-889

Cable, communications 3ft. (1m) - used to download to computer or printer 

204-844

*Handheld printer - prints report directly from DRS 

40-477

Door switch kit - used for logging door openings 


* Handheld printer (optional) 204-1020 used with adapter cable 204-1031.

Specifications are subject to change without notice. For more information, contact your local dealer.

 
 

Other Service Parts Categories:

 
 

Email info@filipinasthermoking.com