Description
The CSR-40 PowerSaver Plus is a one-piece, integral front wall, all-electric automatic cooling and heating unit for ISO sea-going containers. It is suitable for operation on trailer on flat car (TOFC), container on flat car (COFC), and aboard ship. |
|
Heating Capacity
System net heating capacity (including motor heat with 60 Hz electric power):
- 5,880 Watts (5,056 KCal/hr, 20,068 Btu/hr). |
|
Refrigeration Capacity
Zer-O™ system net cooling capacities at 37.8°C (100°F) ambient and 60 Hz electric power. |
|
Temperature |
|
|
|
Temperature |
Watts |
KCal/hr |
Blu/hr |
|
21ºC
or 70ºF |
13,805 |
11,868 |
47,100 |
|
2ºC
or 35ºF |
10,200 |
8,769 |
34,800 |
|
-18ºC
or 0ºF |
6,009 |
5,166 |
20,500 |
|
-29ºC
or -20ºF |
4,045 3,477 13,800 |
2,671 |
10,600 |
|
|
Dimensions
(with reciprocating compressor) |
|
|
|
Weight |
413 kgs |
(910 lbs) |
|
Height |
2,235 mm |
(88 in) |
|
Width |
2,026 mm |
(79.8 in) |
|
Depth |
420 mm |
(16.5 in) |
|
|
|
|
Standard Features
|
-
R-134a refrigerant
- Scroll compressor:
Exclusive Copeland® Glacier™ hermetic scroll compressor
with Demand Cooling™, and ambient compensated internal overload and high-temperature protection
- Type: hermetic Compliant Scroll® (one staionary and one orbiting), with radial and axial compliance allowing tolerance to liquid refrigerant and debris
- Rating: 6hp motor, 380/460V, 50/60 Hz
- Construction: steel shell with rigid internal mount of scroll and motor
- Oil: polyol ester
- Paint finish: corrosion-resistive paint
- Microprocessor controller
The µP-3000 microprocessor controller provides thermostat, digital thermometer programming keypad, mode indicators, and a digital status readout window for displaying electronically recorded trip and cargo information
- µP-3000 includes PTI programs, manual test, self-diagnostic test, advanced service information and service help functions
:
- An optional USDA-approved data recorder records
operating conditions up to 365 days
- The controller contains the following basic features and
components:
- Backlit LCD digital display
- Mode indication LEDs
- Alarm indicator functions
- Defrost cycle control
- Internal self-checking/diagnostics
- Pre-trip testing for reefer unit
- Remote monitoring and data retrevial interface ports
- Data recording
- Electronic phase selection
- 3-phase current monitoring & protection
- Power consumption control to limit total unit power
consumption
- Proportional-integrated differential(PID) refrigeration capacity control system
- Non-corrosive sea-going construction includes
marine-treated aluminum alloy frame, non-corrosive fittings,
all stainless steel hardware, receiver tank, water-based
lacquer-coated condenser coil, hydrophilic coating on
evaporator coil, and a marine duty protective coating on the
compressor
- Condenser and evaporator fan motors include stainless
steel shafts and internal thermal overload protection
- CFC-free foamed-in-place insulation
- Evaporator fan airflow:
|
High
Speed
|
m³/h |
cfm |
|
60Hz:
12.7 mm (0.50 in) WG
|
5,603 |
3,300 |
|
30Hz:
19.0 mm (0.75 in) WG
|
5,094 |
3,000 |
| |
Evaporator
fans operate on demand depending on cargo and ambient
temperature to reduce power draw from fan motors
|
- Fresh air exchange adjustable from 0-285 m³/hr
(0-150 ft³/min)
- Unit wired for 380/460V, 3-phase, 50/60 HZ power
supply with an 18 meter (60 ft) 11/4 power cable with CEE-17
plug
- Bottom air discharge
- Automatic electronic phase correction system
- 24 Vac control system
- Demand defrost and supplemental timed defrost
- Manual defrost initiation via µP-3000 keypad
- Cool, Modulation Cool, Null, Heat, Defrost, In-Range and
alarm indicator lights
- Time delay start sequence
- ABS certification
- Composite condenser and evaporator fans
- Conforms to ISO classifications and specification for
thermal containers including racking and end loading
standards, TIR specifications, ATP refrigeration
standards, ARI standards for rating refrigeration
capacity, UIC international Union of Railways, Australian
Electrical Certification, British Standard 3755 Requirement
(TAINT), USDA requirements for "Insect Cold"
treatment, and Agrotechnological Research Institute (ATO-DLO)
for flower bulb transportation
- Auxiliary battery and charger
- USDA "Cold Treatment" provision
- Bulb mode
|
|
Optional Features
|
- Dual-voltage transformer
- Water-cooled condenser
- Humidity control
- De-humidity control
- 4-pin remote monitoring receptacle
- Partlow temperature recorder
- Saginomiya temperature recorder
- Remote monitoring
- Suction/discharge pressure gauges
- Transfresh provision
- 10/4 power cable
- AFAM or AFAM+
|
|
Specifications are subject to change without notice.